Examination Of Energy Efficiency For Mac

Автор:

The energy-efficiency analytical DQ-MAC model in non-saturation conditions is compared to 802.15.4 MAC energy-consumption analysis presented by Bougard in and a state-of-the-art energy-saving BSN-MAC.

The fact that the IEEE 802.15.4 MAC does not fully satisfy the strict wireless body sensor network (BSN) requirements in healthcare systems highlights the need for the design and analysis of new scalable MAC solutions, which guarantee low power consumption to all specific sorts of body sensors and traffic loads. While taking the challenging healthcare requirements into account, this paper aims for the study of energy consumption in BSN scenarios. For that purpose, the IEEE 802.15.4 MAC limitations are first examined, and other potential MAC layer alternatives are further explored. Our intent is to introduce energy-aware radio activation polices into a high-performance distributed queuing medium access control (DQ-MAC) protocol and evaluate its energy-saving achievements, as a function of the network load and the packet length. To do so, a fundamental energy-efficiency theoretical analysis for DQ-MAC protocols is hereby for the first time provided.

By means of computer simulations, its performance is validated using IEEE 802.15.4 MAC system parameters. Although the challenges faced by wireless body sensor networks (BSNs) in healthcare environments are in a certain way similar to those already existing in current wireless sensor networks (WSNs), there are intrinsic differences which require special attention. For instance, human body monitoring may be achieved by attaching sensors to the body's surface as well as implanting them into tissues for a more accurate clinical practice. Some of these newly emerged challenges, due to healthcare requirements, range from low latency and high reliability (i.e., quality of service), to low power consumption in order to protect human tissue.

Hence, one of the major concerns in BSNs is that of extreme energy efficiency, which is also the key to extend the lifetime of battery-powered body sensors, reduce maintenance costs, and avoid invasive procedures to replace battery in the case of implantable devices. While taking healthcare requirements into consideration, in this paper, we concentrate on the evaluation of energy consumption in the Medium Access Control (MAC) layer. For that purpose, we introduce a new energy-efficiency theoretical analysis of a Distributed Queuing MAC (DQ-MAC) protocol and evaluate its performance under BSN scenarios. Please note that the optimization design and evaluation of the here characterized DQ-MAC protocol in terms of quality of service was presented in under BSN scenarios considering specific medical settings. The resulted protocol with integrated cross-layer fuzzy-logic scheduling techniques was renamed to Distributed Queuing Body Area Network (DQBAN) MAC protocol. Generally speaking, the MAC layer is responsible for coordinating channel accesses, by avoiding collisions and scheduling data transmissions, to maximize throughput efficiency at an acceptable packet delay and minimal energy consumption.

In this context, among all IEEE 802 standards available today, the IEEE 802.15.4 (802.15.4) is regarded as the technology of choice for most BSN research studies , –. However, even though the 802.15.4 MAC consumes very low power, the figures may not reach the levels required in BSNs ,. This is the reason why there exists the need to explore other MAC potential candidates for future BSNs , –, which might be potential candidates for other BSN-targeted standardization bodies, such as the IEEE 802.15.6 task group.A lot of work has been done on reducing the power consumption since the first standardization of the 802.15.4 MAC in 2003. Most of the proposed low-powered MAC layer protocols are contention based (CSMA) and can be put into either, one of the two classifications, synchronous or asynchronous.

The basic idea behind a synchronous MAC is to let the sensors sleep periodically, and to have them somehow aware of each other's sleeping schedules. In order to work efficiently, a very basic requirement is to have sensors tightly coupled or synchronized to each other. Some synchronous protocols found in the literature are S-MAC and T-MAC.

S-MAC introduces periodic coordinated sleep/wakeup duty cycles, and as a result, the battery lifetime for sensors is increased. One problem of S-MAC is that the duty cycle requires to be tuned to a specific traffic load. Thus, its performance suffers under varying traffic loads. The T-MAC sleeping technique satisfies the varying traffic requirements.

The T-MAC also uses an adaptive listening technique in neighbor's transmissions, and sensors are able to immediately pass the data, avoiding the timeout introduced in T-MAC. Therefore, as T-MAC duty cycle varies adaptively, this improves the energy and throughput performance under varying traffic loads.The asynchronous techniques employ a completely different approach. They append a long enough preamble to the data packets that ensures that the destination became active at least once while the preamble was being transmitted. B-MAC uses a technique that allows sensors to sleep without them having to be aware of each other's schedules or without being synchronized. It is a simple protocol which uses long preambles to eliminate the need of synchronization.

However, B-MAC somehow suffers from energy inefficiency due to the new introduced overhead, since all nodes in the sphere of influence require listening to the long preambles. X-MAC takes the concepts of B-MAC further and comes up with techniques to reduce the length of the preamble by putting useful information in the preamble. X-MAC avoids overhearing by putting the destination address in the preamble, that is, unconcerned sensors come to know just by listening to a part of the preamble that the data packet is not intended for them, and thus they go back to sleep. MFP-MAC's greatest achievement is the reduction of idle listening and overhearing avoidance in broadcast traffic.

Idle listening is reduced by having the preamble divided into sequence numbered microframes. This way each sensor knows when the current data will be put.The BSN-MAC is a dedicated ultra-low-power adaptive MAC protocol designed for star-based topology BSNs based on 802.15.4 MAC. By exploiting feedback information from distributed sensors in the BSN, the BSN-MAC protocol adjusts protocol parameters dynamically to achieve best energy conservation on energy-critical body sensors. The same authors of BSN-MAC published thereafter the H-MAC , which is a novel Time Division Multiple Access (TDMA) MAC protocol especially designed for biosensors in BSNs. It improves energy efficiency by exploiting human heartbeat rhythm information to perform time synchronization for TDMA. By following the heartbeat rhythm, wireless biosensors can achieve time synchronization without having to turn on their radio to receive periodic timing information from a central controller, so that energy cost for time synchronization can be completely avoided and the lifetime of the BSN can be prolonged. Another energy-efficient TDMA-based MAC protocol for wireless BSNs is the BodyMAC , which uses flexible and efficient bandwidth allocation schemes and sleep mode to meet the dynamic requirements of BSNs.

In , the authors compared BodyMAC with 802.15.4 MAC. To reduce energy consumption in a BSN, the authors in designed a collision-free protocol, where all communication is initiated by the central node and is addressed uniquely to a slave node.All of these protocols try to reduce some of the commonly identified sources of energy loss: idle listening, collisions, overhearing, or protocol overhead. On the one hand, purely contention-based protocols such as S-MAC , T-MAC , B-MAC , X-MAC , and MFP-MAC are not energy-efficient enough for real-time monitoring applications in BSNs. On the other hand, the problem with TDMA-based protocols might be the bandwidth under utilization whenever there is a BSN with heterogeneous traffic. This is the main reason why we suggested the use of the DQ-MAC family, which grants immediate access for light traffic loads and seamlessly moves to a reservation system for high traffic loads, eliminating collisions for all data transmissions.

The optimisation introduced in proves how DQBAN is able to cope with constant and heterogeneous traffic in two different medical scenarios under BSNs, assuming that the central node is unconstrained in energy (e.g., central care unit) and is always reachable (see Figure ). DQBAN energy-efficiency performance remains the same as the one analyzed in this paper without the optimization introduced in. Here, apart from providing a new theoretical energy-consumption analysis in nonsaturation conditions, an energy-efficiency comparison between DQ-MAC performance and that of the standard facto 802.15.4 MAC and the BSN-MAC is portrayed.

BSN-MAC has been selected as a reference benchmark for its similarity in terms of design as well as structure, and studied scenarios in. Current 802.15.4 MAC limitations for BSNs are formulated in Section 2. Section 3 follows with a brief overview of the most relevant specifications regarding DQ-MAC protocols. Section 4 introduces significant DQ-MAC protocol enhancements to minimize energy consumption in BSNs. The newly proposed energy-efficiency analysis in non-saturation conditions and the adopted energy-aware radio activation policy are presented in Section 5.

The model validation and the performance evaluation by means of computer simulations are shown in Section 6. The last section concludes the paper. The 802.15.4 MAC accepts three network topologies: star, peer to peer, and cluster tree. Our focus is here on 1-hop star-based BSNs, where a body area network (BAN) coordinator is elected. In a hospital BSN, the BAN coordinator can be a central care unit linked to a number of ward patients wearing several body sensors (see Figure ).

Communication from body sensors to BAN coordinator ( uplink), from BAN coordinator to body sensors ( downlink), or even from body sensor to body sensor ( ad hoc) is possible. In the following, we study uplink and downlink communications, which occurs more often than ad hoc communication for regular patient monitoring BSNs. In a 802.15.4 star-based network, the beacon mode appears to allow for the greatest energy efficiency.

Indeed, it allows the transceiver to be completely switched off up to 15/16 of the time when nothing is transmitted/received, while still allowing the transceiver to be synchronized to the network and able to transmit or receive a packet at any time. The beacon mode introduces the so-called superframe structure. The inter-beacon period is partially or entirely occupied by the superframe, which is divided into 16 slots. Among them, there are at most 7 guaranteed time slots (GTS), (i.e., they are dedicated to specific nodes), which form the contention-free period (CFP). This functionality targets very low-latency applications, but it is not scalable in BSNs, since the number of dedicated slots is not sufficient. Further, most of the time, a device uses only a small portion of the allocated GTS slots, and the major portion remains unused, resulting in empty holes within the CFP (i.e., bandwidth under utilization). In the medical field, where one illness usually boost up other illnesses, many body sensors should be able to reach the BAN coordinator via such guaranteed services.In such conditions, the use of the contention access period (CAP) is required, where channel accesses in the uplink are coordinated by a slotted carrier sense multiple access mechanism with collision avoidance (CSMA/CA).

Nevertheless, it has already been proved that the CSMA/CA mechanism, used within the CAP, has a significant negative impact on the overall energy consumption, as the traffic load in the network steadily increases –. In , the authors suggested that physical level improvements, such as energy-aware radio activation policies, should be combined with other MAC optimizations to allow for more energy-efficient wireless networks.

Thus, the appraisal of other existing MAC protocols in terms of effective energy per information bit introduces important challenges in BSNs. This is the reason why we here introduce energy-aware radio activation policies into a high-performance MAC protocol different from CSMA/CA, while analyzing and evaluating its energy-saving performance in BSNs. In the literature, it is already possible to find some research work on reducing the power consumption of the standard de facto 802.15.4 MAC in BSN scenarios ,. The Body Sensor Network MAC (BSN-MAC) is based on 802.15.4 MAC supporting both star and peer-to-peer network topologies. The authors in concentrate also on a 1-hop star-based topology, since in their analyzed BSN, the number of sensors is limited and an external mobile device, such as PDA or cell phone, acts as a BAN coordinator. However, the promising accomplishment of the DQBAN protocol in terms of quality of service under healthcare requirements in hospital settings , evokes the idea to further explore and analyze the energy-efficiency of this family of DQ-MAC protocols (i.e., , –) in general BSN scenarios.

In –, DQ-MAC favorable behavior (especially versus CSMA/CA) is achieved thanks to the inherent protocol performance at eliminating collisions in data transmissions and minimizing the overhead of contention procedures (i.e., carrier sensing and backoff periods). Based on that, we propose here a novel DQ-MAC energy-efficiency theoretical analysis for non-saturation conditions and evaluate its performance in front of 802.15.4 MAC and BSN-MAC in BSN scenarios, bearing medical applications in mind. Please note that in order to cope with healthcare stringent requirements of quality of service, the same authors introduced new cross-layer fuzzy-logic scheduling techniques into the here proposed DQ-MAC protocol and evaluate its performance in terms of reliability and maximum latency in different hospital settings. The results proved to show the suitability of the here presented DQ-MAC protocol in more specific healthcare BSN scenarios.

This section highlights the basic features related to DQ-MAC protocols that are essential for the understanding of the new energy-saving enhancements and energy-efficient theoretical analysis proposed in this paper. The introduction of the Distributed Queuing Random Access Protocol (DQRAP) for local wireless communications was already presented in and later in under the name of Distributed Queuing Collision Avoidance (DQCA), as an adaptation to IEEE 802.11b MAC environments. It has already been shown that the throughput performance of a DQ-MAC protocol outperforms CSMA/CA in all studied scenarios. The main characteristic of a DQ-MAC protocol is that it behaves as a random access mechanism under low traffic conditions, and switches smoothly and automatically to a reservation scheme when the traffic load grows, that is, DQ-MAC protocols show a near-optimum performance independent of the amount of active terminals and traffic load.Let us consider a star-based topology with several nodes and a network coordinator, following DQRAP original description , the time axis is divided into an 'access subslot' that is further divided into access minislots ( m) and a 'data subslot.' The basic idea is to concentrate user access requests in the access minislots, while the 'data subslot' is devoted to collision-free data transmissions (see Figures and ). The DQRAP analytical model approaches the delay, and throughput performance of the theoretical is in charge of the data server (the 'data subslot'). This provides a collision resolution tree algorithm that optimum queuing systems M/M/1 or G/D/1, depending on the traffic distribution.

Hence, DQ-MAC protocols can be modeled as if every station in the system maintains two common logical distributed queues—the collision resolution queue (CRQ) and the data transmission queue (DTQ)—physically implemented as four integers in each station; two station-dependant integers that represent the occupied position in each queue; two further integers shared among all stations in the system that visualize the total number of stations in each queue, CRQ and DTQ (see Figure ). The CRQ controls station accesses to the collision resolution server (the access minislots), while the DTQ proves to be stable for every traffic load even over the system transmission capacity. Note that the number of access minislots is implementation dependant, but we are formally using 3 access minislots, following the original DQRAP structure and argumentation for maximizing its throughput performance. Figure shows the superframe format of a DQ-MAC protocol proposal in a possible star-based BSN scenario. There might be several ward patients wearing a number of body sensors that communicate to a central care unit (i.e., BAN coordinator), as portrayed in Figure. The complete energy-saving superframe structure comprises two differential parts:. (i)from body sensors to BAN coordinator ( uplink), with a CAP and a CFP.

The CAP is further divided into m access minislots, whereas the CFP is devoted to collision-free data packet transmissions;. (ii)from BAN coordinator to body sensors ( downlink) using the feedback frame, which contains several strategic fields.In fact, the DQ-MAC superframe is bounded by the feedback packet (FBP) contained in the feedback frame as portrayed in Figures and which is broadcasted by the BAN coordinator.Similar to the 802.15.4 MAC superframe format, one of the main uses of the FBP is to synchronize the attached body sensors to the BAN coordinator. The FBP always contains relevant MAC control information (i.e., corresponding also to the protocol rules), which is essential for the right functioning of all body sensors in the BSN. When a body sensor wishes to transfer data, it first waits for the FBP. After synchronization, it independently actualizes the integer counters, by applying a set of rules that determine its position in the protocol distributed queues, CRQ and DTQ (see Figure ).

At the appropriate time, the body sensor transmits either an access request sequence (ARS), of duration, in one of the randomly selected access minislots(within the CAP), or its data packet in the contention-free data slot of duration (within the CFP). The BAN coordinator may acknowledge the successful reception of the data packet by sending an optional acknowledgment frame (ACK). This sequence is summarized in the energy-saving DQ-MAC superframe depicted in Figure.All in all, the main differences of this energy-saving DQ-MAC superframe format in Figure with respect to the previous DQ-MAC protocols – the following:.

(1)A preamble (PRE) is newly introduced within the broadcasted feedback frame, concretely between the ACK and the FPB, to enable synchronization after power-sleep modus (i.e., either idle or shutdown, see , ). The intuitive reasoning is the following: (i) the feedback frame is an aggregation of an ACK and the FBP in order to save PHY header overhead and therefore energy consumption at reception, that is, the ACK is essential only to the body sensor, which transmitted in the previous contention-free data slot. Hence, body sensors can prolong their power-sleep modus until the immediate reception of the FBP; (ii) the precise position of the PRE between the ACK and the FBP is mainly due to scalability in terms of energy efficiency. This means that in a future system design, several ACKs may be aggregated just before the preamble (PRE). Body sensors within the DQ-MAC system not being addressed in this multicast/aggregated communication shall only receive the FBP.

This is the reason why a preamble is suitable in this explicit position. Cadillacs and dinosaurs 2 rom. (2)FBP is here of fixed length (i.e., independent of the number of sensors in the BSN) and contains two new fields for specific energy-saving purposes, the modulation and coding scheme (MCS) and length of the packet being transmitted in the next contention-free data slot (i.e., in the next CFP). This facilitates independent energy-aware radio activation policies, so that body sensors can calculate the time they can remain in power-sleep modus (see ).

Further, the MCS field is also thought for future multirate medical applications in BSNs (i.e., scalability in terms of application-oriented medical body sensors).Note that the FBP always contains a specific field named QDR (Queuing Discipline Rules), which contains the updating information regarding the aforementioned ARS (see –). Additionally, there is the possibility to transmit data packets of variable length ( ), using the same frame structure, at the same time that energy-saving benefits are maintained, which means a flexible CFP.It must be pointed out that a similar DQ-MAC superframe format approach using the preamble and the above-depicted FBP have already been proposed by the same authors in , , though studied in totally different scenarios and conditions. In , the DQBAN protocol commitment is to guarantee that all packet transmissions are served within their particular application-dependant quality-of-service requirements (i.e., reliability and message latency), without endangering body sensors battery lifetime within BSNs in medical scenarios. For that purpose, the authors propose a cross-layer fuzzy-logic scheduling algorithm to deal with multiple cross-layer input variables of diverse nature in an independent manner. Note that the introduction of the fuzzy-logic techniques does not change the energy-consumption performance of the depicted protocol.

In , a preliminary analytical evaluation of the enhanced DQ-MAC protocol is presented under general WSN scenarios in saturation conditions. Though following the same line as in terms of DQ-MAC energy-saving superframe format, this paper aims to analyze the non-saturation DQ-MAC energy-efficiency performance in BSNs, mainly completing the work in in a broadened scenario. Without loss of generality, it is now considered that all body sensors in our studied scenario (see Figure ) generate Poisson-distributed data messages, whose length is an exponential random variable with average bits. Recall from Figure the DQ-MAC superframe structure, and notice that is the payload length within the CFP expressed in bits. All body sensors generate here the same average traffic load, and the total packet arrival rate is (packets/superframe), where we define 'packet' as the fraction of a message of length in bits. The average service rate of the system is further explained thereafter and denoted by (packets/superframe).

For this theoretical analysis, we use the whole DQ-MAC superframe duration as the time unit, and we denote by the number of DQ-MAC superframe units (see Figure ).As previously mentioned, a DQ-MAC statistical model approaches the delay and throughput performance of the theoretical optimum queuing systems M/M/1, or G/D/1, depending on the traffic distribution (i.e., M: exponential, G: general, and D: deterministic). DQ-MAC protocol can be modeled as if every body sensor in the system maintains two common logical distributed queues—CRQ and DTQ—as portrayed in Figure. The CRQ controls body sensor accesses to the collision resolution server (the access minislots) and is designed to resolve collisions among stations attempting to successfully obtain an access minislot.

The DTQ, in charge of the data server (the 'data subslot'), is used to buffer the data packets that have obtained permission to transmit and are awaiting their scheduled time of departure using a first-come-first-served (FCFS) discipline. The enable transmission interval (ETI), modeled with a nonqueuing infinite server system in Figure, is the time elapsed from the actual arrival time of a packet to the head of the CRQ subsystem at the beginning of the next DQ-MAC superframe, when the contention process can start. The first queuing system models the CRQ subsystem and the second represents the DTQ subsystem.

DQ-MAC Model (M/M/1)DQ-MAC energy-efficiency analysis applying Markov queuing theory can only be done in stable conditions, that is., when the input rate of a system denoted by (packets/superframe) is at most equal to the average service rate of the system denoted by (packets/superframe), that is, the stability condition can be expressed as. Otherwise, the system becomes unstable and the queue might grow indefinitely, that is, not all arrivals are eventually served. The M/M/1 queuing model, with an interarrival and service-time distribution exponential, and an infinite queuing server, is considered as one of the simplest birth-death processes. As aforementioned, DQ-MAC can be modeled as a queuing system that consists of two statistical queuing subsystems. The CRQ subsystem is evaluated using M/M/1 Markov chain. The DTQ subsystem is modeled as a G/D/1.Here, the input rate is the ratio of the average number of newly arrived packets of bits—generated in messages—per DQ-MAC superframe unit.

The average service rate is the ratio of served packets per DQ-MAC superframe unit and is computed as. (1)where is the probability to find successfully an empty access minislot. We can with confidence make the assumption that the input traffic follows a Poisson process with input rate and that the CRQ service time for a packet follows an exponential distribution with average service rate, as shown in. It is also possible to see that the input rate of the DTQ subsystem is, for, and the average service rate, that is, G/D/1.Based on the delay analysis approach of , we define here the DQ-MAC system delay with the term as the total number of DQ-MAC superframes a body sensor remains in the DQ-MAC system for each specific packet it requires to transmit. First, let us consider a residual time in ETI (expressed in number of DQ-MAC superframes), waiting for a new DQ-MAC superframe, where a body sensor may send an ARS within the access minislots.

In case of collision, the body sensor remains in CRQ until it is the turn to transmit an ARS in another access minislot. Hence, expressed in DQ-MAC superframes, is the CRQ waiting plus the service time (CRQ subsystem). Similarly, represents the DTQ waiting time plus the DTQ service time in DQ-MAC superframes (DTQ subsystem). So, the average total delay a body sensor's packet remains in DQ-MAC system model can be computed as. (2)where for each packet,.

(i)is the average residual DQ-MAC superframes in ETI (i.e., by default 0.5 units ),. (ii)is the average number of DQ-MAC superframes in the CRQ subsystem, and. (iii)is the average number of DQ-MAC superframes in the DTQ subsystem.Further, based on the delay model of DQ-MAC protocol in , we can treat CRQ as an M/M/1 system. Thus, applying the average service rate of (1) and the input rate to the M/M/1 queue, we achieve the average delay of the CRQ subsystem as.

(4)where the input rate of the DTQ subsystem is for, as aforementioned. Energy-Aware Radio Activation PolicyFigure illustrates the energy-aware radio activation policy following DQ-MAC adapted energy-saving superframe format as in Figure. This allows different power management scenarios of body sensors using DQ-MAC under BSNs.

Note that each body sensor synchronizes to the BSN thanks to the novel preamble sequence (PRE) of duration after a period in idle mode. Thereafter, it receives the required system information via the FBP of duration for updating its distributed queues, CRQ and DTQ. After each FBP, a short interframe space is left for processing purposes like in 802.15.4. Active body sensors involved in the access procedure like in scenarios and start by sending an ARS, here of duration length, in one of the randomly selected access minislots. Prior to that, these body sensors should have switched their radio from idle to transmit mode, which take them a transition time for body sensor radio wakeup (i.e., from idle to active modes ). Next, scenario depicts the transmission of a previously granted packet of duration length preceded by the transition time. If the packet is received correctly, an ACK of duration is sent back to the transmitting body sensor together with the FBP after a maximum time, during which the receiver turns its radio to idle mode to save energy.

In , is characterized as the maximum time to wait for an ACK. Scenario shows how an active body sensor waiting in idle mode synchronizes through the preamble sequence to receive the FBP. Finally, scenario portrays how a body sensor in shutdown state wakes up and waits for some time in idle mode to synchronize through the preamble and get the FBP to update the state of its CRQ and DTQ queues. Energy-Efficiency Theoretical AnalysisLet us first define and as the power consumption (in W) in.